The documentation from version 39.5.17 of PLANTA project can be found in the new PLANTA Online Help.

DT404 Submodule

DI028040 SUBMOD

Here, the ID of the submodule is entered.

DI040930 Submodule

Module title of the submodule

DI040813 Positioning

Determines the position of the submodule in the panel

Values

  • 0: Tab (the position of the submodule is dependent on the values in Dock to module here).
  • 1: Right
  • 2: · Links
  • 3: Bottom
  • 4: Top

See also: General information on panels, panel customizing

DI040814 Module size

If the submodule is not full screen (Positioning is nonzero), this data field defines the size of the submodule.

Details

  • Permissible values: between 0 and 1 (= 100 %).
Example
  • 0,3 = 30 % of the window size

DI028201 Code

This parameter defines along with the Docking to module parameter which module the submodule is docked to.

Notes

  • Together with Positioning, these two parameters determine the position of the submodule in the panel.
  • The Code must be unique, therefore a sequential number should be used.
    • If the Code is not unique, the submodule will have no menu.

DI040812 Docking to the module

Here it is defined, which module the submodule will be docked to.

Values

  • Code of another submodule: Dock to this module.
  • 0: The module is displayed as a tab behind the main module.
  • -1:
    • Positioning = 0: The module is displayed as a tab to the right of the main module.
    • Positioning = 1-4: The module is displayed in the floating/fixes module window at the position defined in the Positionierung parameter (dependent on the Auto Hide parameter).

Notes

  • In Docking to module, there must not be the same value as in the Code data field. This is prevented by a value range.
  • The docking module is to be positioned in front of the modules that are docked.

DI040902 Foreground

Defines, which submodule is displayed in the foreground

Note

  • If this parameter is not set for any module, the main module is displayed in the foreground.

DI040903 Auto hide

Defines, whether the submodule is displayed as a floating or fixed module window. It only takes effect when Positioning = 1-4 and Docking to module = -1.

Values

  • Checked: Submodule is displayed as a floating module window.
  • Unchecked: Submodule is displayed as a fixed module window.

DI040811 Run macro

Defines, whether the macro of the submodule is run when the module is launched.

Values

  • Checked: Macro is run when the module is launched.
  • Unchecked: Macro is not run when the module is launched.

DI059306 Display

Defines, whether the submodule is loaded, i.e.displayed in the panel, when the main module is launched.

Values

  • Checked: Submodule is loadedwhen its main module is loaded.
  • Unchecked: Submodule is not loaded when its main module is loaded.

DI027898 Pos.

Sequence in which the submodules are opened

DI028117 Variant

Currently without function