The documentation from version 39.5.17 of PLANTA project can be found in the new PLANTA Online Help.

Scales

Information

  • In modules, the scale must always be customized above the corresponding scale objects.

Time Scale

Information

  • Time scale data items form time scales under which time-related objects (e.g. bars, number values etc.) can be positioned.
  • A scale DI always represents a grid for a scale area.
  • scale areas are formed from several scale data fields.

Creating a scale-DI

  • Create a time scale DI with Class = 3 for DT400 Other objects in the Data Dictionary module
  • Allocate a time scale to the newly created time scale-DI
    • in the Data Items module. For sub-DIs:
      • Define functions in the Function field.
      • Allocate the symbols in this field: For this purpose, enter the required symbol ID in the SUBDI symbol ID field.

New in C 39.5.9

Notes for today lines
  • The today line is a firm part of each scale That is why it also has a fixed layout.
  • If a deviating layout for the today line is required, e.g., a different color or invisible, the today line must be customized.
    • To do so, a scale DI with Function = TL must be adopted and the ID of the required symbol must be stored in the SUBDI symbol ID field.

Creating a scale area

Histogram Scale

Information

  • The histogram scale enables histogram bars to be displayed together with a time scale.
  • Unlike time scale DIs, the histogram scale DI is not customized in a specific scale area. It is adopted to the same data area as the histogram bars.

Procedure

  • Create a histogram DI with Class = 12 for DT400 Other objects in the Data Dictionary module
  • DB type determines the formatting of the histogram scale grid in the module.
    • Example:
      • DF type N8 allows for a grid with decimal places.
      • DF type N4 only allows 9 digits before the decimal point and no decimal places.
  • Assign the Grid Line sub DI to the histogram scale DI
    • define its function and
    • allocate the symbols
    • in the Data Items module.

Details

New in C 39.5.9

Notes for today lines
  • The today line is a firm part of each scale That is why it also has a fixed layout.
  • If a deviating layout for the today line is required, e.g., a different color or invisible, the today line must be customized.
    • To do so, a scale DI with Function = TL must be adopted and the ID of the required symbol must be stored in the SUBDI symbol ID field.

Scale Objects

Date Bar

Information

  • Date bars are used to display the duration of , e.g., tasks in the form of bars below a time scale.
  • A date bar is a complex DI, which can change its symbol depending on sub-DIs (milestone, critical, non-critical, completed, etc.).

Procedure

  • Create a time scale DI with Class = 1 for DT400 Other objects in the Data Dictionary module
  • In the Data Items module,
    • assign two arbitrary sub-DIs of the DF type = D (Date) to the bar DI:
      • assign a start date DI with Function = SD and
      • an end date DI with Function = ED.
    • Assign symbols. The symbol assignment defines the display of the bars in the module.
      • The required symbol in the Symbol DI field is assigned to a bar without traffic light function.
        • Example in the standard: the Requested date bar (DI002001)
      • In case the bar changes its display depending on different values (traffic light function), further sub-DIs are assigned.
        • This sub-DIs have the function A or D. Their customizing equates to the customizing of traffic light sub-DIs.
          • Example in the standard: the date bar of the calculated dates (DI002951)
          • The order or dominance of the sub-DIs is defined via the Pos. parameter.
      • A combination of both variants is possible, too. In this case
        • the sub-DI symbols overwrite the DI symbol
        • If no condition of the sub-DIs is satisfied, the DI symbol is displayed.
          • Example in the standard: the actual date bar (DI002005)
      • All sub-DIs must originate from the same or a parent data table.

Notes

Histogram Bars

Information

  • Histogram bars display values as bars below a scale. It must be possible to assign the values to a date.

Procedure

Notes Histogram bars can only be displayed if a data field of the “Histogram scale” type is assigned above them.

Linkage

Information

  • DIs of this Class are used for the display of structures, especially for network structures, e.g., for links in the Gantt chart.
  • A linkage data item is displayed in modules as a line between two objects. Their appearance is determined by the sub-DI symbols.

Procedure

Details

Projection

Information

  • Projection data items display numerical values under a time scale.
  • Numeric values must be assignable to a date.

Procedure

  • Create a time scale DI with Class = 11 for DT400 Other objects in the Data Dictionary module.
  • Assign sub DIs to the projection DI
    • in the Data Items module.
      • Define the sub DIs as follows:
        • one or multiple sub-DIs with Function = T and
        • one or multiple sub-DIs with Function = W
    • If necessary, carry out the preallocation in the Summarization type field.
      • If a deviating value is entered in the field of the same name on data field level upon embedding the DI into a module, the deviating value takes effect.

Details

  • The value (V) is displayed below the time scale at the position that corresponds to the date D.
  • If the module construction requires multiple values to be projected, you can either create a projection DI for each value or only one protection DI with multiple sub-DIs with Function = W.
  • Number formats are ineffective on projection data fields, since they are not numeric. They have to be set in the DI (function W).
  • Customizing of modules with protection

         PLANTA project









 
  • Suche in Topic-Namen

  • Suche in Topic-Inhalten
This site is powered by the TWiki collaboration platform Powered by Perl